Rulon Bearings

AK Steel TRAN-COR® H-0 CARLITE® DR® Grain Oriented Electrical Steel
Categories: Metal; Electronic/Magnetic Alloy; Ferrous Metal

Material Notes: TRAN-COR H CARLITE® high permeability electrical steels offer an outstanding degree of grain orientation, This combination of higher permeability with low residual stress offers the potential for lower core losses and less noisy transformer core structures, particularly at higher operating inductions, when compared to conventional grain oriented electrical steels. The core loss characteristics are further enhanced in the TRAN-COR H CARLITE DR® (Domain Refined) products where laser scribing is employed. In this process, a precisely focused laser beam is rapidly scanned across the steel surface. The micro-strain imparted into the material forces the pre-existing magnetic domains to subdivide. The finer domain structure reduces the distance that the domain walls must move during AC magnetization, thereby reducing eddy current losses. The result is far lower core loss than possible with conventional grain oriented electrical steels of comparable thickness. TRAN-COR H CARLITE products are suitable for all types of transformers while TRAN-COR H DR products are suitable for those types of transformers where a stress relief annealing treatment of the magnetic core is not used. Stress relief annealing will result in the eradication of the effect provided by the laser treatment and will result in a significant increase in core loss.

Information provided by AK Steel.

Vendors: No vendors are listed for this material. Please click here if you are a supplier and would like information on how to add your listing to this material.
 
Physical PropertiesMetricEnglishComments
Density 7.65 g/cc0.276 lb/in³
Thickness 200 - 240 microns7.87 - 9.45 mil
 230 microns9.06 milNominal
 
Mechanical PropertiesMetricEnglishComments
Knoop Microhardness 173173
Hardness, Rockwell B 8383
Tensile Strength, Ultimate 359 MPa52100 psiIn rolling direction
Tensile Strength, Yield 345 MPa50000 psiIn rolling direction
Elongation at Break 11 %11 %In 2", rolling direction
Modulus of Elasticity 113.8 GPa16510 ksiIn rolling direction
 138 GPa20000 ksiAt 20° to rolling direction
 203 GPa29400 ksiAt 90° to rolling direction
 241 GPa35000 ksiAt 45° to rolling direction
 276 GPa40000 ksiAt 55° to rolling direction
 
Electrical PropertiesMetricEnglishComments
Exciting Power (RMS)  0.00165 RMS AT/cm
@Magnetic Field 0.100 T,
Frequency 50 Hz
0.00260 RMS VA/lb
@Magnetic Field 0.100 T,
Frequency 50 Hz
ASTM A804, 0.23 mm
 0.00209 RMS AT/cm
@Magnetic Field 0.100 T,
Frequency 60 Hz
0.00330 RMS VA/lb
@Magnetic Field 0.100 T,
Frequency 60 Hz
ASTM A804, 0.23 mm
 0.00576 RMS AT/cm
@Magnetic Field 0.200 T,
Frequency 50 Hz
0.00910 RMS VA/lb
@Magnetic Field 0.200 T,
Frequency 50 Hz
ASTM A804, 0.23 mm
 0.00721 RMS AT/cm
@Magnetic Field 0.200 T,
Frequency 60 Hz
0.0114 RMS VA/lb
@Magnetic Field 0.200 T,
Frequency 60 Hz
ASTM A804, 0.23 mm
 0.0120 RMS AT/cm
@Magnetic Field 0.300 T,
Frequency 50 Hz
0.0190 RMS VA/lb
@Magnetic Field 0.300 T,
Frequency 50 Hz
ASTM A804, 0.23 mm
 0.0151 RMS AT/cm
@Magnetic Field 0.300 T,
Frequency 60 Hz
0.0238 RMS VA/lb
@Magnetic Field 0.300 T,
Frequency 60 Hz
ASTM A804, 0.23 mm
 0.0199 RMS AT/cm
@Magnetic Field 0.400 T,
Frequency 50 Hz
0.0315 RMS VA/lb
@Magnetic Field 0.400 T,
Frequency 50 Hz
ASTM A804, 0.23 mm
 0.0251 RMS AT/cm
@Magnetic Field 0.400 T,
Frequency 60 Hz
0.0397 RMS VA/lb
@Magnetic Field 0.400 T,
Frequency 60 Hz
ASTM A804, 0.23 mm
 0.0294 RMS AT/cm
@Magnetic Field 0.500 T,
Frequency 50 Hz
0.0465 RMS VA/lb
@Magnetic Field 0.500 T,
Frequency 50 Hz
ASTM A804, 0.23 mm
 0.0372 RMS AT/cm
@Magnetic Field 0.500 T,
Frequency 60 Hz
0.0588 RMS VA/lb
@Magnetic Field 0.500 T,
Frequency 60 Hz
ASTM A804, 0.23 mm
 0.0403 RMS AT/cm
@Magnetic Field 0.600 T,
Frequency 50 Hz
0.0637 RMS VA/lb
@Magnetic Field 0.600 T,
Frequency 50 Hz
ASTM A804, 0.23 mm
 0.0511 RMS AT/cm
@Magnetic Field 0.600 T,
Frequency 60 Hz
0.0807 RMS VA/lb
@Magnetic Field 0.600 T,
Frequency 60 Hz
ASTM A804, 0.23 mm
 0.0528 RMS AT/cm
@Magnetic Field 0.700 T,
Frequency 50 Hz
0.0834 RMS VA/lb
@Magnetic Field 0.700 T,
Frequency 50 Hz
ASTM A804, 0.23 mm
 0.06675 RMS AT/cm
@Magnetic Field 0.800 T,
Frequency 50 Hz
0.1055 RMS VA/lb
@Magnetic Field 0.800 T,
Frequency 50 Hz
ASTM A804, 0.23 mm
 0.06700 RMS AT/cm
@Magnetic Field 0.700 T,
Frequency 60 Hz
0.1059 RMS VA/lb
@Magnetic Field 0.700 T,
Frequency 60 Hz
ASTM A804, 0.23 mm
 0.08282 RMS AT/cm
@Magnetic Field 0.900 T,
Frequency 50 Hz
0.1309 RMS VA/lb
@Magnetic Field 0.900 T,
Frequency 50 Hz
ASTM A804, 0.23 mm
 0.08485 RMS AT/cm
@Magnetic Field 0.800 T,
Frequency 60 Hz
0.1341 RMS VA/lb
@Magnetic Field 0.800 T,
Frequency 60 Hz
ASTM A804, 0.23 mm
 0.1018 RMS AT/cm
@Magnetic Field 1.00 T,
Frequency 50 Hz
0.1609 RMS VA/lb
@Magnetic Field 1.00 T,
Frequency 50 Hz
ASTM A804, 0.23 mm
 0.1055 RMS AT/cm
@Magnetic Field 0.900 T,
Frequency 60 Hz
0.1668 RMS VA/lb
@Magnetic Field 0.900 T,
Frequency 60 Hz
ASTM A804, 0.23 mm
 0.1245 RMS AT/cm
@Magnetic Field 1.10 T,
Frequency 50 Hz
0.1968 RMS VA/lb
@Magnetic Field 1.10 T,
Frequency 50 Hz
ASTM A804, 0.23 mm
 0.1294 RMS AT/cm
@Magnetic Field 1.00 T,
Frequency 60 Hz
0.2045 RMS VA/lb
@Magnetic Field 1.00 T,
Frequency 60 Hz
ASTM A804, 0.23 mm
 0.1522 RMS AT/cm
@Magnetic Field 1.20 T,
Frequency 50 Hz
0.2405 RMS VA/lb
@Magnetic Field 1.20 T,
Frequency 50 Hz
ASTM A804, 0.23 mm
 0.1585 RMS AT/cm
@Magnetic Field 1.10 T,
Frequency 60 Hz
0.2505 RMS VA/lb
@Magnetic Field 1.10 T,
Frequency 60 Hz
ASTM A804, 0.23 mm
 0.1863 RMS AT/cm
@Magnetic Field 1.30 T,
Frequency 50 Hz
0.2945 RMS VA/lb
@Magnetic Field 1.30 T,
Frequency 50 Hz
ASTM A804, 0.23 mm
 0.193 RMS AT/cm
@Magnetic Field 1.20 T,
Frequency 60 Hz
0.305 RMS VA/lb
@Magnetic Field 1.20 T,
Frequency 60 Hz
ASTM A804, 0.23 mm
 0.2287 RMS AT/cm
@Magnetic Field 1.40 T,
Frequency 50 Hz
0.3614 RMS VA/lb
@Magnetic Field 1.40 T,
Frequency 50 Hz
ASTM A804, 0.23 mm
 0.2356 RMS AT/cm
@Magnetic Field 1.30 T,
Frequency 60 Hz
0.3723 RMS VA/lb
@Magnetic Field 1.30 T,
Frequency 60 Hz
ASTM A804, 0.23 mm
 0.2819 RMS AT/cm
@Magnetic Field 1.50 T,
Frequency 50 Hz
0.4455 RMS VA/lb
@Magnetic Field 1.50 T,
Frequency 50 Hz
ASTM A804, 0.23 mm
 0.2876 RMS AT/cm
@Magnetic Field 1.40 T,
Frequency 60 Hz
0.4545 RMS VA/lb
@Magnetic Field 1.40 T,
Frequency 60 Hz
ASTM A804, 0.23 mm
 0.3523 RMS AT/cm
@Magnetic Field 1.50 T,
Frequency 60 Hz
0.5568 RMS VA/lb
@Magnetic Field 1.50 T,
Frequency 60 Hz
ASTM A804, 0.23 mm
 0.3532 RMS AT/cm
@Magnetic Field 1.60 T,
Frequency 50 Hz
0.5582 RMS VA/lb
@Magnetic Field 1.60 T,
Frequency 50 Hz
ASTM A804, 0.23 mm
 0.4383 RMS AT/cm
@Magnetic Field 1.60 T,
Frequency 60 Hz
0.6927 RMS VA/lb
@Magnetic Field 1.60 T,
Frequency 60 Hz
ASTM A804, 0.23 mm
 0.4774 RMS AT/cm
@Magnetic Field 1.70 T,
Frequency 50 Hz
0.7545 RMS VA/lb
@Magnetic Field 1.70 T,
Frequency 50 Hz
ASTM A804, 0.23 mm
 0.5867 RMS AT/cm
@Magnetic Field 1.70 T,
Frequency 60 Hz
0.9273 RMS VA/lb
@Magnetic Field 1.70 T,
Frequency 60 Hz
ASTM A804, 0.23 mm
 0.82536 RMS AT/cm
@Magnetic Field 1.80 T,
Frequency 50 Hz
1.3045 RMS VA/lb
@Magnetic Field 1.80 T,
Frequency 50 Hz
ASTM A804, 0.23 mm
 1.0008 RMS AT/cm
@Magnetic Field 1.80 T,
Frequency 60 Hz
1.5818 RMS VA/lb
@Magnetic Field 1.80 T,
Frequency 60 Hz
ASTM A804, 0.23 mm
 2.8558 RMS AT/cm
@Magnetic Field 1.90 T,
Frequency 50 Hz
4.5136 RMS VA/lb
@Magnetic Field 1.90 T,
Frequency 50 Hz
ASTM A804, 0.23 mm
 3.5057 RMS AT/cm
@Magnetic Field 1.90 T,
Frequency 60 Hz
5.5409 RMS VA/lb
@Magnetic Field 1.90 T,
Frequency 60 Hz
ASTM A804, 0.23 mm
Electrical Resistivity 0.0000500 ohm-cm0.0000500 ohm-cm
 
Magnetic PropertiesMetricEnglishComments
Core Loss  0.00289 W/kg
@Magnetic Field 0.100 T,
Frequency 50 Hz
0.00131 W/lb
@Magnetic Field 0.100 T,
Frequency 50 Hz
ASTM A804, 0.23 mm
 0.00385 W/kg
@Magnetic Field 0.100 T,
Frequency 60 Hz
0.00175 W/lb
@Magnetic Field 0.100 T,
Frequency 60 Hz
ASTM A804, 0.23 mm
 0.01082 W/kg
@Magnetic Field 0.200 T,
Frequency 50 Hz
0.004908 W/lb
@Magnetic Field 0.200 T,
Frequency 50 Hz
ASTM A804, 0.23 mm
 0.01451 W/kg
@Magnetic Field 0.200 T,
Frequency 60 Hz
0.006582 W/lb
@Magnetic Field 0.200 T,
Frequency 60 Hz
ASTM A804, 0.23 mm
 0.0236 W/kg
@Magnetic Field 0.300 T,
Frequency 50 Hz
0.0107 W/lb
@Magnetic Field 0.300 T,
Frequency 50 Hz
ASTM A804, 0.23 mm
 0.0317 W/kg
@Magnetic Field 0.300 T,
Frequency 60 Hz
0.0144 W/lb
@Magnetic Field 0.300 T,
Frequency 60 Hz
ASTM A804, 0.23 mm
 0.0413 W/kg
@Magnetic Field 0.400 T,
Frequency 50 Hz
0.0187 W/lb
@Magnetic Field 0.400 T,
Frequency 50 Hz
ASTM A804, 0.23 mm
 0.0554 W/kg
@Magnetic Field 0.400 T,
Frequency 60 Hz
0.0251 W/lb
@Magnetic Field 0.400 T,
Frequency 60 Hz
ASTM A804, 0.23 mm
 0.0635 W/kg
@Magnetic Field 0.500 T,
Frequency 50 Hz
0.0288 W/lb
@Magnetic Field 0.500 T,
Frequency 50 Hz
ASTM A804, 0.23 mm
 0.0852 W/kg
@Magnetic Field 0.500 T,
Frequency 60 Hz
0.0386 W/lb
@Magnetic Field 0.500 T,
Frequency 60 Hz
ASTM A804, 0.23 mm
 0.0903 W/kg
@Magnetic Field 0.600 T,
Frequency 50 Hz
0.0410 W/lb
@Magnetic Field 0.600 T,
Frequency 50 Hz
ASTM A804, 0.23 mm
 0.121 W/kg
@Magnetic Field 0.600 T,
Frequency 60 Hz
0.0549 W/lb
@Magnetic Field 0.600 T,
Frequency 60 Hz
ASTM A804, 0.23 mm
 0.1218 W/kg
@Magnetic Field 0.700 T,
Frequency 50 Hz
0.05525 W/lb
@Magnetic Field 0.700 T,
Frequency 50 Hz
ASTM A804, 0.23 mm
 0.1578 W/kg
@Magnetic Field 0.800 T,
Frequency 50 Hz
0.07158 W/lb
@Magnetic Field 0.800 T,
Frequency 50 Hz
ASTM A804, 0.23 mm
 0.1628 W/kg
@Magnetic Field 0.700 T,
Frequency 60 Hz
0.07384 W/lb
@Magnetic Field 0.700 T,
Frequency 60 Hz
ASTM A804, 0.23 mm
 0.1984 W/kg
@Magnetic Field 0.900 T,
Frequency 50 Hz
0.08999 W/lb
@Magnetic Field 0.900 T,
Frequency 50 Hz
ASTM A804, 0.23 mm
 0.211 W/kg
@Magnetic Field 0.800 T,
Frequency 60 Hz
0.0957 W/lb
@Magnetic Field 0.800 T,
Frequency 60 Hz
ASTM A804, 0.23 mm
 0.244 W/kg
@Magnetic Field 1.00 T,
Frequency 50 Hz
0.111 W/lb
@Magnetic Field 1.00 T,
Frequency 50 Hz
ASTM A804, 0.23 mm
 0.265 W/kg
@Magnetic Field 0.900 T,
Frequency 60 Hz
0.120 W/lb
@Magnetic Field 0.900 T,
Frequency 60 Hz
ASTM A804, 0.23 mm
 0.296 W/kg
@Magnetic Field 1.10 T,
Frequency 50 Hz
0.134 W/lb
@Magnetic Field 1.10 T,
Frequency 50 Hz
ASTM A804, 0.23 mm
 0.325 W/kg
@Magnetic Field 1.00 T,
Frequency 60 Hz
0.147 W/lb
@Magnetic Field 1.00 T,
Frequency 60 Hz
ASTM A804, 0.23 mm
 0.354 W/kg
@Magnetic Field 1.20 T,
Frequency 50 Hz
0.161 W/lb
@Magnetic Field 1.20 T,
Frequency 50 Hz
ASTM A804, 0.23 mm
 0.394 W/kg
@Magnetic Field 1.10 T,
Frequency 60 Hz
0.179 W/lb
@Magnetic Field 1.10 T,
Frequency 60 Hz
ASTM A804, 0.23 mm
 0.418 W/kg
@Magnetic Field 1.30 T,
Frequency 50 Hz
0.190 W/lb
@Magnetic Field 1.30 T,
Frequency 50 Hz
ASTM A804, 0.23 mm
 0.470 W/kg
@Magnetic Field 1.20 T,
Frequency 60 Hz
0.213 W/lb
@Magnetic Field 1.20 T,
Frequency 60 Hz
ASTM A804, 0.23 mm
 0.487 W/kg
@Magnetic Field 1.40 T,
Frequency 50 Hz
0.221 W/lb
@Magnetic Field 1.40 T,
Frequency 50 Hz
ASTM A804, 0.23 mm
 0.555 W/kg
@Magnetic Field 1.30 T,
Frequency 60 Hz
0.252 W/lb
@Magnetic Field 1.30 T,
Frequency 60 Hz
ASTM A804, 0.23 mm
 0.565 W/kg
@Magnetic Field 1.50 T,
Frequency 50 Hz
0.256 W/lb
@Magnetic Field 1.50 T,
Frequency 50 Hz
ASTM A804, 0.23 mm
 0.570 W/kg
@Magnetic Field 1.50 T,
Frequency 50 Hz
0.259 W/lb
@Magnetic Field 1.50 T,
Frequency 50 Hz
Typical
 0.648 W/kg
@Magnetic Field 1.40 T,
Frequency 60 Hz
0.294 W/lb
@Magnetic Field 1.40 T,
Frequency 60 Hz
ASTM A804, 0.23 mm
 0.655 W/kg
@Magnetic Field 1.60 T,
Frequency 50 Hz
0.297 W/lb
@Magnetic Field 1.60 T,
Frequency 50 Hz
ASTM A804, 0.23 mm
 0.750 W/kg
@Magnetic Field 1.50 T,
Frequency 60 Hz
0.340 W/lb
@Magnetic Field 1.50 T,
Frequency 60 Hz
ASTM A804, 0.23 mm
 0.750 W/kg
@Magnetic Field 1.50 T,
Frequency 60 Hz
0.340 W/lb
@Magnetic Field 1.50 T,
Frequency 60 Hz
Typical
 0.770 W/kg
@Magnetic Field 1.70 T,
Frequency 50 Hz
0.349 W/lb
@Magnetic Field 1.70 T,
Frequency 50 Hz
Typical
 0.773 W/kg
@Magnetic Field 1.70 T,
Frequency 50 Hz
0.351 W/lb
@Magnetic Field 1.70 T,
Frequency 50 Hz
ASTM A804, 0.23 mm
 0.800 W/kg
@Magnetic Field 1.70 T,
Frequency 50 Hz
0.363 W/lb
@Magnetic Field 1.70 T,
Frequency 50 Hz
Maximum
 0.867 W/kg
@Magnetic Field 1.60 T,
Frequency 60 Hz
0.393 W/lb
@Magnetic Field 1.60 T,
Frequency 60 Hz
ASTM A804, 0.23 mm
 0.967 W/kg
@Magnetic Field 1.80 T,
Frequency 50 Hz
0.439 W/lb
@Magnetic Field 1.80 T,
Frequency 50 Hz
ASTM A804, 0.23 mm
 1.01 W/kg
@Magnetic Field 1.70 T,
Frequency 60 Hz
0.458 W/lb
@Magnetic Field 1.70 T,
Frequency 60 Hz
Typical
 1.017 W/kg
@Magnetic Field 1.70 T,
Frequency 60 Hz
0.4613 W/lb
@Magnetic Field 1.70 T,
Frequency 60 Hz
ASTM A804, 0.23 mm
 1.06 W/kg
@Magnetic Field 1.70 T,
Frequency 60 Hz
0.481 W/lb
@Magnetic Field 1.70 T,
Frequency 60 Hz
Maximum
 1.264 W/kg
@Magnetic Field 1.80 T,
Frequency 60 Hz
0.5733 W/lb
@Magnetic Field 1.80 T,
Frequency 60 Hz
ASTM A804, 0.23 mm
 1.365 W/kg
@Magnetic Field 1.90 T,
Frequency 50 Hz
0.6192 W/lb
@Magnetic Field 1.90 T,
Frequency 50 Hz
ASTM A804, 0.23 mm
 1.766 W/kg
@Magnetic Field 1.90 T,
Frequency 60 Hz
0.8010 W/lb
@Magnetic Field 1.90 T,
Frequency 60 Hz
ASTM A804, 0.23 mm
 
Descriptive Properties
Approximate Equivalent International GradeM080-23P5
Magnetostriction 10^8-18ASTM A876, 1.4T, 60Hz, 0.27 mm
 -20ASTM A876, 1.5T, 60Hz, 0.27 mm
 -20ASTM A876, 1.6T, 60Hz, 0.27 mm
 -21ASTM A876, 1.7T, 60Hz, 0.27 mm
Maximum Induction at 800 A/m (T)1.88
Minimum Lamination Factor (%)94.5
Typical Induction at 800 A/m (T)1.916
Typical Lamination Factor (%)96.6

Some of the values displayed above may have been converted from their original units and/or rounded in order to display the information in a consistent format. Users requiring more precise data for scientific or engineering calculations can click on the property value to see the original value as well as raw conversions to equivalent units. We advise that you only use the original value or one of its raw conversions in your calculations to minimize rounding error. We also ask that you refer to MatWeb's terms of use regarding this information. Click here to view all the property values for this datasheet as they were originally entered into MatWeb.

Users viewing this material also viewed the following:
AK Steel DI-MAX® HF-10 Nonoriented Electrical Steel (Extended Electrical/Magnetic Data)
AK Steel TRAN-COR® H-2 CARLITE® Grain Oriented Electrical Steel
AK Steel TRAN-COR® H-0 CARLITE® Grain Oriented Electrical Steel
AK Steel TRAN-COR® H-1 CARLITE® DR® Grain Oriented Electrical Steel
AK Steel TRAN-COR® H-1 CARLITE® Grain Oriented Electrical Steel

NAKS166 / 140762

Aluminum Castings

Please read our License Agreement regarding materials data and our Privacy Policy. Questions or comments about MatWeb? Please contact us at info@matweb.com. We appreciate your input.

The contents of this web site, the MatWeb logo, and "MatWeb" are Copyright 1996-2025 by MatWeb, LLC. MatWeb is intended for personal, non-commercial use. The contents, results, and technical data from this site may not be reproduced either electronically, photographically or substantively without permission from MatWeb, LLC.