Haynes Hastelloy® B-3® alloy, after elevated temperature exposure
Categories: Metal; Nonferrous Metal; Nickel Alloy; Superalloy

Material Notes: The attributes of Corrosion-Resistant HASTELLOY® alloys include high resistance to uniform attack, outstanding localized corrosion resistance, excellent stress corrosion cracking resistance, and ease of welding and fabrication. Same excellent resistance to hydrochloric acid and other strongly reducing chemicals as B-2 alloy, but with significantly better thermal stability, fabricability and stress corrosion cracking resistance.

In The As-Welded Condition HASTELLOY® B-3® alloy is an additional member of the nickel-molybdenum family of alloys with excellent resistance to hydrochloric acid at all concentrations and temperatures. It also withstands sulfuric, acetic, formic and phosphoric acids, and other nonoxidizing media. B-3 alloy has excellent resistance to pitting corrosion, to stress-corrosion cracking and to knife-line and heat-affected zone attack.

The improved thermal stability of HASTELLOY B-3 alloy minimizes the problems associated with fabrication of B-2 alloy components. This is due to the reduced tendency to precipitate deleterious intermetallic phases in B-3 alloy, thereby, affording it greater ductility than B-2 alloy during and following various thermal cycling conditions. HASTELLOY B-3 alloy has good overall forming and welding characteristics. It may be forged or otherwise hotworked, providing that it is held at 2250°F (1230°C) for a time sufficient to bring the entire piece to temperature. Since it is a low carbon alloy, the use of lower hot finishing temperatures may be necessary to achieve grain size control. B-3 alloy may also be formed by cold working. Although it does work-harden somewhat rapidly, B-3 alloy components can be made using all common cold forming techniques. Limited tests in boiling 20 percent hydrochloric acid indicate that the uniform corrosion resistance of B-3 alloy is not affected by cold reductions up to 50 percent as compared to that of the alloy in the solution heat-treated condition.

B-3 alloy can be welded by all common welding techniques, although oxyacetylene and submerged arc welding processes are not recommended when the fabricated item is to be used in corrosive service. Special precautions should be taken to avoid excessive heat input.

Heat Treatment: All wrought forms of HASTELLOY B-3 alloy are furnished in the solution heat treated condition unless otherwise specified. B-3 alloy is solution heat-treated at 1950°F (1065°C) and rapid quenched, except for bright annealed sheet or coil products which are heat-treated at 2100°F (1150°C) and cooled in hydrogen.

Applications: HASTELLOY B-3 alloy is suitable for use in all applications previously requiring the use of HASTELLOY B-2 alloy. Like B-2 alloy, B-3 is not recommended for use in the presence of ferric or cupric salts as these salts may cause rapid corrosion failure. Ferric or cupric salts may develop when hydrochloric acid comes in contact with iron or copper.

ASME Boiler And Pressure Vessel Code

ASME has published Code Case 2140 for solution annealed HASTELLOY B-3 alloy

Data provided by the manufacturer, Haynes International, Inc.

Key Words: UNS N10675; ASTM B333 (plate, sheet and strip), ASTM B335 (bar), ASTM B366 (welded fittings), ASTM B564 (forgings), ASTM B619 (welded pipe), ASTM B622 (seamless pipe and tube) and ASTM B626 (welded tube)
Vendors: Visit metalmen for your metals needs. Products include special chemistry, tight tolerances, custom tempers, odd dimensions/forms, and small quantities. Phone 1-800-767-9494.

Click here to view all available suppliers for this material.

Please click here if you are a supplier and would like information on how to add your listing to this material.

 
Physical PropertiesOriginal ValueComments
Density 9.22 g/ccat RT
 
Mechanical PropertiesOriginal ValueComments
Tensile Strength, Ultimate 860 MPa
@Temperature 25.0 °C
No thermal exposure, Sheet
 885 MPa
@Temperature 25.0 °C
No thermal exposure, Plate
 870 MPa
@Treatment Temp. 425 °C,
Time 2.88e+7 sec
Room temp test after thermal exposure
 880 MPa
@Treatment Temp. 425 °C,
Time 4.32e+7 sec
Room temp test after thermal exposure
 900 MPa
@Treatment Temp. 425 °C,
Time 3.60e+6 sec
Room temp test after thermal exposure
 905 MPa
@Treatment Temp. 425 °C,
Time 1.44e+7 sec
Room temp test after thermal exposure
 915 MPa
@Treatment Temp. 425 °C,
Time 5.76e+7 sec
Room temp test after thermal exposure
 960 MPa
@Treatment Temp. 480 °C,
Time 2.88e+7 sec
Room temp test after thermal exposure
 970 MPa
@Treatment Temp. 480 °C,
Time 3.60e+6 sec
Room temp test after thermal exposure
 975 MPa
@Treatment Temp. 480 °C,
Time 4.32e+7 sec
Room temp test after thermal exposure
 995 MPa
@Treatment Temp. 480 °C,
Time 1.44e+7 sec
Room temp test after thermal exposure
 1005 MPa
@Treatment Temp. 540 °C,
Time 3.60e+6 sec
Room temp test after thermal exposure
 1020 MPa
@Treatment Temp. 480 °C,
Time 5.76e+7 sec
Room temp test after thermal exposure
 1050 MPa
@Treatment Temp. 540 °C,
Time 2.88e+7 sec
Room temp test after thermal exposure
 1055 MPa
@Treatment Temp. 540 °C,
Time 1.44e+7 sec
Room temp test after thermal exposure
 1060 MPa
@Treatment Temp. 540 °C,
Time 4.32e+7 sec
Room temp test after thermal exposure
 1120 MPa
@Treatment Temp. 540 °C,
Time 5.76e+7 sec
Room temp test after thermal exposure
 1165 MPa
@Treatment Temp. 595 °C,
Time 3.60e+6 sec
Room temp test after thermal exposure
 1210 MPa
@Treatment Temp. 595 °C,
Time 2.88e+7 sec
Room temp test after thermal exposure
 1230 MPa
@Treatment Temp. 595 °C,
Time 4.32e+7 sec
Room temp test after thermal exposure
 1230 MPa
@Treatment Temp. 595 °C,
Time 1.44e+7 sec
Room temp test after thermal exposure
 1280 MPa
@Treatment Temp. 595 °C,
Time 5.76e+7 sec
Room temp test after thermal exposure
Tensile Strength, Yield 400 MPa
@Temperature 25.0 °C
No thermal exposure, Plate; 0.2% offset
 420 MPa
@Temperature 25.0 °C
No thermal exposure, Sheet; 0.2% offset
 395 MPa
@Treatment Temp. 425 °C,
Time 2.88e+7 sec
Room temp test after thermal exposure; 0.2% offset
 405 MPa
@Treatment Temp. 425 °C,
Time 4.32e+7 sec
Room temp test after thermal exposure; 0.2% offset
 405 MPa
@Treatment Temp. 425 °C,
Time 3.60e+6 sec
Room temp test after thermal exposure; 0.2% offset
 410 MPa
@Treatment Temp. 425 °C,
Time 1.44e+7 sec
Room temp test after thermal exposure; 0.2% offset
 410 MPa
@Treatment Temp. 425 °C,
Time 5.76e+7 sec
Room temp test after thermal exposure; 0.2% offset
 535 MPa
@Treatment Temp. 480 °C,
Time 3.60e+6 sec
Room temp test after thermal exposure; 0.2% offset
 555 MPa
@Treatment Temp. 480 °C,
Time 2.88e+7 sec
Room temp test after thermal exposure; 0.2% offset
 565 MPa
@Treatment Temp. 480 °C,
Time 4.32e+7 sec
Room temp test after thermal exposure; 0.2% offset
 570 MPa
@Treatment Temp. 540 °C,
Time 3.60e+6 sec
Room temp test after thermal exposure; 0.2% offset
 580 MPa
@Treatment Temp. 480 °C,
Time 1.44e+7 sec
Room temp test after thermal exposure; 0.2% offset
 590 MPa
@Treatment Temp. 480 °C,
Time 5.76e+7 sec
Room temp test after thermal exposure; 0.2% offset
 615 MPa
@Treatment Temp. 540 °C,
Time 1.44e+7 sec
Room temp test after thermal exposure; 0.2% offset
 625 MPa
@Treatment Temp. 540 °C,
Time 2.88e+7 sec
Room temp test after thermal exposure; 0.2% offset
 635 MPa
@Treatment Temp. 540 °C,
Time 4.32e+7 sec
Room temp test after thermal exposure; 0.2% offset
 660 MPa
@Treatment Temp. 540 °C,
Time 5.76e+7 sec
Room temp test after thermal exposure; 0.2% offset
 720 MPa
@Treatment Temp. 595 °C,
Time 3.60e+6 sec
Room temp test after thermal exposure; 0.2% offset
 810 MPa
@Treatment Temp. 595 °C,
Time 1.44e+7 sec
Room temp test after thermal exposure; 0.2% offset
 815 MPa
@Treatment Temp. 595 °C,
Time 2.88e+7 sec
Room temp test after thermal exposure; 0.2% offset
 830 MPa
@Treatment Temp. 595 °C,
Time 4.32e+7 sec
Room temp test after thermal exposure; 0.2% offset
 870 MPa
@Treatment Temp. 595 °C,
Time 5.76e+7 sec
Room temp test after thermal exposure; 0.2% offset
Elongation at Break 53.4 %
@Temperature 25.0 °C
No thermal exposure, Sheet; in 2 in sample
 57.8 %
@Temperature 25.0 °C
No thermal exposure, Plate; in 2 in sample
 25.3 %
@Treatment Temp. 595 °C,
Time 5.76e+7 sec
Room temp test after thermal exposure; in 2 in sample
 26.4 %
@Treatment Temp. 595 °C,
Time 4.32e+7 sec
Room temp test after thermal exposure; in 2 in sample
 28.7 %
@Treatment Temp. 595 °C,
Time 2.88e+7 sec
Room temp test after thermal exposure; in 2 in sample
 31.5 %
@Treatment Temp. 595 °C,
Time 1.44e+7 sec
Room temp test after thermal exposure; in 2 in sample
 38.8 %
@Treatment Temp. 595 °C,
Time 3.60e+6 sec
Room temp test after thermal exposure; in 2 in sample
 43.7 %
@Treatment Temp. 540 °C,
Time 5.76e+7 sec
Room temp test after thermal exposure; in 2 in sample
 44.2 %
@Treatment Temp. 540 °C,
Time 4.32e+7 sec
Room temp test after thermal exposure; in 2 in sample
 45.6 %
@Treatment Temp. 540 °C,
Time 1.44e+7 sec
Room temp test after thermal exposure; in 2 in sample
 47.1 %
@Treatment Temp. 540 °C,
Time 2.88e+7 sec
Room temp test after thermal exposure; in 2 in sample
 48.3 %
@Treatment Temp. 480 °C,
Time 1.44e+7 sec
Room temp test after thermal exposure; in 2 in sample
 48.4 %
@Treatment Temp. 540 °C,
Time 3.60e+6 sec
Room temp test after thermal exposure; in 2 in sample
 48.8 %
@Treatment Temp. 480 °C,
Time 5.76e+7 sec
Room temp test after thermal exposure; in 2 in sample
 48.9 %
@Treatment Temp. 480 °C,
Time 2.88e+7 sec
Room temp test after thermal exposure; in 2 in sample
 49.9 %
@Treatment Temp. 480 °C,
Time 4.32e+7 sec
Room temp test after thermal exposure; in 2 in sample
 50 %
@Treatment Temp. 480 °C,
Time 3.60e+6 sec
Room temp test after thermal exposure; in 2 in sample
 56.8 %
@Treatment Temp. 425 °C,
Time 1.44e+7 sec
Room temp test after thermal exposure; in 2 in sample
 57.2 %
@Treatment Temp. 425 °C,
Time 3.60e+6 sec
Room temp test after thermal exposure; in 2 in sample
 57.4 %
@Treatment Temp. 425 °C,
Time 2.88e+7 sec
Room temp test after thermal exposure; in 2 in sample
 57.5 %
@Treatment Temp. 425 °C,
Time 4.32e+7 sec
Room temp test after thermal exposure; in 2 in sample
 57.6 %
@Treatment Temp. 425 °C,
Time 5.76e+7 sec
Room temp test after thermal exposure; in 2 in sample
Reduction of Area 67.5 %
@Temperature 25.0 °C
No thermal exposure, Plate
 21.7 %
@Treatment Temp. 595 °C,
Time 4.32e+7 sec
Room temp test after thermal exposure
 29.6 %
@Treatment Temp. 595 °C,
Time 5.76e+7 sec
Room temp test after thermal exposure
 35.7 %
@Treatment Temp. 595 °C,
Time 2.88e+7 sec
Room temp test after thermal exposure
 37.2 %
@Treatment Temp. 595 °C,
Time 1.44e+7 sec
Room temp test after thermal exposure
 54.9 %
@Treatment Temp. 595 °C,
Time 3.60e+6 sec
Room temp test after thermal exposure
 57.5 %
@Treatment Temp. 540 °C,
Time 5.76e+7 sec
Room temp test after thermal exposure
 59.2 %
@Treatment Temp. 540 °C,
Time 4.32e+7 sec
Room temp test after thermal exposure
 59.5 %
@Treatment Temp. 540 °C,
Time 2.88e+7 sec
Room temp test after thermal exposure
 61.4 %
@Treatment Temp. 540 °C,
Time 1.44e+7 sec
Room temp test after thermal exposure
 64.4 %
@Treatment Temp. 480 °C,
Time 2.88e+7 sec
Room temp test after thermal exposure
 64.6 %
@Treatment Temp. 480 °C,
Time 5.76e+7 sec
Room temp test after thermal exposure
 64.7 %
@Treatment Temp. 540 °C,
Time 3.60e+6 sec
Room temp test after thermal exposure
 65.2 %
@Treatment Temp. 480 °C,
Time 4.32e+7 sec
Room temp test after thermal exposure
 65.5 %
@Treatment Temp. 480 °C,
Time 1.44e+7 sec
Room temp test after thermal exposure
 67.1 %
@Treatment Temp. 480 °C,
Time 3.60e+6 sec
Room temp test after thermal exposure
 70.4 %
@Treatment Temp. 425 °C,
Time 4.32e+7 sec
Room temp test after thermal exposure
 70.5 %
@Treatment Temp. 425 °C,
Time 2.88e+7 sec
Room temp test after thermal exposure
 71.4 %
@Treatment Temp. 425 °C,
Time 5.76e+7 sec
Room temp test after thermal exposure
 71.6 %
@Treatment Temp. 425 °C,
Time 1.44e+7 sec
Room temp test after thermal exposure
 71.7 %
@Treatment Temp. 425 °C,
Time 3.60e+6 sec
Room temp test after thermal exposure
Modulus of Elasticity 216 GPaRT
 147 GPa
@Temperature 1000 °C
 157 GPa
@Temperature 900 °C
 168 GPa
@Temperature 800 °C
 178 GPa
@Temperature 700 °C
 185 GPa
@Temperature 600 °C
 190 GPa
@Temperature 500 °C
 197 GPa
@Temperature 400 °C
 202 GPa
@Temperature 300 °C
 208 GPa
@Temperature 200 °C
 213 GPa
@Temperature 100 °C
Charpy Impact 358 J
 11.0 J
@Treatment Temp. 595 °C,
Time 5.76e+7 sec
Notched, Room temp test after thermal exposure
 18.0 J
@Treatment Temp. 595 °C,
Time 2.88e+7 sec
Notched, Room temp test after thermal exposure
 18.0 J
@Treatment Temp. 595 °C,
Time 4.32e+7 sec
Notched, Room temp test after thermal exposure
 20.0 J
@Treatment Temp. 595 °C,
Time 1.44e+7 sec
Notched, Room temp test after thermal exposure
 34.0 J
@Treatment Temp. 595 °C,
Time 3.60e+6 sec
Notched, Room temp test after thermal exposure
 79.0 J
@Treatment Temp. 540 °C,
Time 5.76e+7 sec
Notched, Room temp test after thermal exposure
 79.0 J
@Treatment Temp. 540 °C,
Time 2.88e+7 sec
Notched, Room temp test after thermal exposure
 111 J
@Treatment Temp. 540 °C,
Time 4.32e+7 sec
Notched, Room temp test after thermal exposure
 145 J
@Treatment Temp. 540 °C,
Time 1.44e+7 sec
Notched, Room temp test after thermal exposure
 237 J
@Treatment Temp. 480 °C,
Time 5.76e+7 sec
Notched, Room temp test after thermal exposure
 285 J
@Treatment Temp. 480 °C,
Time 2.88e+7 sec
Notched, Room temp test after thermal exposure
 313 J
@Treatment Temp. 480 °C,
Time 4.32e+7 sec
Notched, Room temp test after thermal exposure
 320 J
@Treatment Temp. 540 °C,
Time 3.60e+6 sec
Notched, Room temp test after thermal exposure
 355 J
@Treatment Temp. 480 °C,
Time 3.60e+6 sec
Notched, Room temp test after thermal exposure
 358 J
@Treatment Temp. 480 °C,
Time 1.44e+7 sec
Notched, Room temp test after thermal exposure
 358 J
@Treatment Temp. 425 °C,
Time 3.60e+6 sec
Notched, Room temp test after thermal exposure
 358 J
@Treatment Temp. 425 °C,
Time 1.44e+7 sec
Notched, Room temp test after thermal exposure
 358 J
@Treatment Temp. 425 °C,
Time 2.88e+7 sec
Notched, Room temp test after thermal exposure
 358 J
@Treatment Temp. 425 °C,
Time 4.32e+7 sec
Notched, Room temp test after thermal exposure
 358 J
@Treatment Temp. 425 °C,
Time 5.76e+7 sec
Notched, Room temp test after thermal exposure
 
Electrical PropertiesOriginal ValueComments
Electrical Resistivity 0.000137 ohm-cmRT
 0.000130 ohm-cm
@Temperature 1000 °C
 0.000132 ohm-cm
@Temperature 900 °C
 0.000137 ohm-cm
@Temperature 800 °C
 0.000137 ohm-cm
@Temperature 100 °C
 0.000137 ohm-cm
@Temperature 200 °C
 0.000138 ohm-cm
@Temperature 300 °C
 0.000138 ohm-cm
@Temperature 400 °C
 0.000140 ohm-cm
@Temperature 500 °C
 0.000142 ohm-cm
@Temperature 700 °C
 0.000143 ohm-cm
@Temperature 600 °C
 
Thermal PropertiesOriginal ValueComments
CTE, linear 11.4 µm/m-°C
@Temperature 25.0 - 300 °C
 11.6 µm/m-°C
@Temperature 25.0 - 400 °C
 11.8 µm/m-°C
@Temperature 25.0 - 600 °C
 11.8 µm/m-°C
@Temperature 25.0 - 500 °C
 12.2 µm/m-°C
@Temperature 25.0 - 700 °C
 13.1 µm/m-°C
@Temperature 25.0 - 800 °C
 13.9 µm/m-°C
@Temperature 25.0 - 900 °C
 14.4 µm/m-°C
@Temperature 25.0 - 1000 °C
Specific Heat Capacity 0.373 J/g-°CRT
 0.382 J/g-°C
@Temperature 100 °C
 0.409 J/g-°C
@Temperature 200 °C
 0.421 J/g-°C
@Temperature 300 °C
 0.431 J/g-°C
@Temperature 400 °C
 0.434 J/g-°C
@Temperature 600 °C
 0.436 J/g-°C
@Temperature 500 °C
 0.575 J/g-°C
@Temperature 1000 °C
 0.577 J/g-°C
@Temperature 900 °C
 0.589 J/g-°C
@Temperature 800 °C
 0.595 J/g-°C
@Temperature 700 °C
Thermal Conductivity 11.2 W/m-KRT
 12.1 W/m-K
@Temperature 100 °C
 13.4 W/m-K
@Temperature 200 °C
 14.8 W/m-K
@Temperature 300 °C
 16.3 W/m-K
@Temperature 400 °C
 17.9 W/m-K
@Temperature 500 °C
 19.6 W/m-K
@Temperature 600 °C
 21.4 W/m-K
@Temperature 700 °C
 21.4 W/m-K
@Temperature 800 °C
 23.3 W/m-K
@Temperature 900 °C
 27.5 W/m-K
@Temperature 1000 °C
Melting Point 1370 - 1418 °C
Solidus 1370 °C
Liquidus 1418 °C
 
Component Elements PropertiesOriginal ValueComments
Aluminum, Al <= 0.50 %
Carbon, C <= 0.010 %
Chromium, Cr 1.5 %
Cobalt, Co <= 3.0 %
Iron, Fe 1.5 %
Manganese, Mn <= 3.0 %
Molybdenum, Mo 28.5 %
Nickel, Ni >= 65 %
Silicon, Si <= 0.10 %
Titanium, Ti <= 0.20 %
Tungsten, W <= 3.0 %
 
Descriptive Properties
Thermal Diffusivity0.003 cm2/sat 25°C
 0.0032 cm2/sat 100°C
 0.0034 cm2/sat 200°C
 0.0037 cm2/sat 300°C
 0.004 cm2/sat 400°C
 0.0044 cm2/sat 500°C
 0.0045 cm2/sat 600°C
 0.0045 cm2/sat 900°C
 0.0047 cm2/sat 800°C
 0.0049 cm2/sat 1000°C
 0.0049 cm2/sat 700°C

Some of the values displayed above may have been converted from their original units and/or rounded in order to display the information in a consistent format. Users requiring more precise data for scientific or engineering calculations can click on the property value to see the original value as well as raw conversions to equivalent units. We advise that you only use the original value or one of its raw conversions in your calculations to minimize rounding error. We also ask that you refer to MatWeb's terms of use regarding this information. Click here to go back to viewing the property data in MatWeb's normal format.

Users viewing this material also viewed the following:
Haynes Hastelloy® B-3® alloy, 0% cold work
Haynes Hastelloy® C-22® alloy, 0.71-3.2 mm thick sheet, solution heat treated
ATI Allvac® Nickelvac® H-B-2 UNS N10665 Nickel Superalloy
Haynes Hastelloy® B-3® alloy, 3.2 mm bright annealed sheet
Haynes Hastelloy® B-3® alloy, heat treated at 1065°C, rapid quenched

NHB3AH / 17036

New MatWeb Services

Please read our License Agreement regarding materials data and our Privacy Policy. Questions or comments about MatWeb? Please contact us at webmaster@matweb.com. We appreciate your input.

The contents of this web site, the MatWeb logo, and "MatWeb" are Copyright 1996-2024 by MatWeb, LLC. MatWeb is intended for personal, non-commercial use. The contents, results, and technical data from this site may not be reproduced either electronically, photographically or substantively without permission from MatWeb, LLC.