Physical Properties | Original Value | Comments |
---|
Specific Gravity | 1.53 g/cc |
Density | 1.51 g/cc |
Filler Content | 17 % |
Water Absorption | 0.17 % |
Moisture Absorption | 0.0700 % |
Viscosity | 105 cP @Shear Rate 1500 1/s, Temperature 260 °C |
Linear Mold Shrinkage, Flow | 0.0050 - 0.0080 cm/cm |
Linear Mold Shrinkage, Transverse | 0.0060 - 0.0090 cm/cm |
Melt Flow | 14 g/10 min @Load 2.16 kg, Temperature 250 °C |
| 40 g/10 min @Load 5.00 kg, Temperature 250 °C |
| 70 g/10 min @Load 5.00 kg, Temperature 265 °C |
| 90 g/10 min @Load 5.00 kg, Temperature 266 °C |
|
Mechanical Properties | Original Value | Comments |
---|
Hardness, Rockwell R | 120 |
Ball Indentation Hardness | 218 MPa |
Tensile Strength at Break | 93.0 MPa |
| 104 MPa |
Tensile Strength, Yield | 93.0 MPa |
| 104 MPa |
Elongation at Break | 2.0 % |
| 2.0 % |
Elongation at Yield | 2.0 % |
| 2.0 % |
Tensile Modulus | 7000 MPa |
| 7100 MPa |
Flexural Strength | 140 MPa |
| 155 MPa |
Flexural Yield Strength | 140 MPa |
| 155 MPa |
Flexural Modulus | 5200 MPa |
| 6100 MPa |
Flexural Strain at Break | 3.0 % |
Izod Impact, Notched | 49.0 J/m |
| 45.0 J/m @Temperature 0.000 °C |
| 45.0 J/m @Temperature -30.0 °C |
Izod Impact, Unnotched | 500 J/m |
| 275 J/m @Temperature -30.0 °C |
Izod Impact, Notched (ISO) | 5.00 kJ/m² |
| 5.00 kJ/m² @Temperature -30.0 °C |
| 5.00 kJ/m² @Temperature 0.000 °C |
Izod Impact, Unnotched (ISO) | 20.0 kJ/m² |
| 20.0 kJ/m² @Temperature -30.0 °C |
Charpy Impact Unnotched | 24.0 kJ/m² |
| 25.0 kJ/m² |
| 20.0 kJ/m² @Temperature -30.0 °C |
| 24.0 kJ/m² @Temperature -30.0 °C |
Charpy Impact, Notched | 5.00 kJ/m² |
| 5.00 kJ/m² |
| 4.00 kJ/m² @Temperature -30.0 °C |
| 5.00 kJ/m² @Temperature -30.0 °C |
Taber Abrasion, mg/1000 Cycles | 16 |
|
Electrical Properties | Original Value | Comments |
---|
Volume Resistivity | 1.00e+15 ohm-cm |
| 1.00e+15 ohm-cm |
Surface Resistance | >= 1.00e+15 ohm |
Dielectric Constant | 3.1 @Frequency 1e+6 Hz |
| 3.2 @Frequency 50.0 - 60.0 Hz |
| 3.4 @Frequency 1e+6 Hz |
Dielectric Strength | 16.0 kV/mm @Thickness 3.20 mm |
| 16.0 kV/mm @Thickness 3.20 mm |
| 19.0 kV/mm @Thickness 1.00 mm |
| 23.0 kV/mm @Thickness 1.60 mm |
| 25.0 kV/mm @Thickness 1.60 mm |
| 29.0 kV/mm @Thickness 0.800 mm |
| 29.0 kV/mm @Thickness 0.800 mm |
Dissipation Factor | 0.0010 @Frequency 50.0 - 60.0 Hz |
| 0.012 @Frequency 1e+6 Hz |
| 0.016 @Frequency 1e+6 Hz |
Arc Resistance | 60 - 120 sec |
Comparative Tracking Index | 150 V |
| 175 V |
| 175 - 250 V |
Hot Wire Ignition, HWI | 15 - 30 sec |
High Amp Arc Ignition, HAI | >= 120 arcs |
High Voltage Arc-Tracking Rate, HVTR | >= 150 mm/min |
|
Thermal Properties | Original Value | Comments |
---|
CTE, linear, Parallel to Flow | 25.7 µm/m-°C @Temperature 23.0 - 150 °C |
| 28.3 µm/m-°C @Temperature -40.0 - 40.0 °C |
| 35.0 µm/m-°C @Temperature 23.0 - 80.0 °C |
CTE, linear, Transverse to Flow | 69.5 µm/m-°C @Temperature -40.0 - 40.0 °C |
| 95.0 µm/m-°C @Temperature 23.0 - 80.0 °C |
| 149 µm/m-°C @Temperature 23.0 - 150 °C |
Thermal Conductivity | 0.190 W/m-K |
Hot Ball Pressure Test | 125 °C |
Deflection Temperature at 0.46 MPa (66 psi) | 210 °C |
| 215 °C |
| 215 °C @Thickness 3.20 mm |
Deflection Temperature at 1.8 MPa (264 psi) | 180 °C |
| 185 °C |
| 190 °C @Thickness 3.20 mm |
Vicat Softening Point | 198 °C |
| 199 °C |
| 199 °C |
| 218 °C |
| 218 °C |
UL RTI, Electrical | 120 °C |
UL RTI, Mechanical with Impact | 120 °C |
UL RTI, Mechanical without Impact | 140 °C |
Flammability, UL94 | V-0 @Thickness 0.900 mm |
| 5VA @Thickness 3.00 mm |
Oxygen Index | 31 % |
Glow Wire Test | 960 °C @Thickness 1.00 mm |
|
Processing Properties | Original Value | Comments |
---|
Processing Temperature | 40.0 - 60.0 °C |
Nozzle Temperature | 240 - 260 °C |
Zone 1 | 230 - 245 °C |
Zone 2 | 240 - 255 °C |
Zone 3 | 245 - 265 °C |
Melt Temperature | 250 - 270 °C |
Mold Temperature | 40.0 - 100 °C |
Drying Temperature | 110 - 120 °C |
Dry Time | 2.00 - 4.00 hour |
Moisture Content | 0.020 % |
Some of the values displayed above may have been converted from their original units and/or rounded in order to
display the information in a consistent format. Users requiring more precise data for scientific or engineering
calculations can click on the property value to see the original value as well as raw conversions to equivalent units.
We advise that you only use the original value or one of its raw conversions in your calculations to minimize rounding
error. We also ask that you refer to MatWeb's
terms of use regarding this information.
Click here to go back to viewing the property data in MatWeb's normal format.