DuPont Mobility and Materials Zytel® 70G30HSL NC010 PA66-GF30
(discontinued **)
Categories:
Polymer
;
Thermoplastic
;
Nylon (Polyamide PA)
;
Nylon 66 (PA66)
;
Nylon 66, 30% Glass Fiber Filled
Material Notes:
30% Glass Reinforced, Heat Stabilized, Polyamide 66
While this product line has been acquired by Celanese, this specific grade had been disconued while still a DuPont product so it is listed here as a discontinued DuPont product.
Vendors:
No vendors are listed for this material. Please
click here
if you are a supplier and would like information on how to add your listing to this material.
Printer friendly version
Download as PDF
Download to Excel (requires Excel and Windows)
Export data to your CAD/FEA program
Add to Folder:
My Folder
Physical Properties
Original Value
Comments
Density
1.37
g/cc
DAM; ISO 1183
Water Absorption
6.0 %
@Thickness 2.00 mm
DAM; Sim. to ISO 62
Moisture Absorption
1.90 %
@Thickness 2.00 mm
DAM; Sim. to ISO 62
Linear Mold Shrinkage, Flow
0.0030
cm/cm
DAM; ISO 294-4, 2577
Linear Mold Shrinkage, Transverse
0.011
cm/cm
DAM; ISO 294-4, 2577
Mechanical Properties
Original Value
Comments
Hardness, Rockwell M
88
50% RH; ISO 2039-2
104
DAM; ISO 2039-2
Hardness, Rockwell R
117
50% RH; ISO 2039-2
124
DAM; ISO 2039-2
Tensile Strength at Break
130
MPa
50% RH; ISO 527-1/-2
200
MPa
DAM; ISO 527-1/-2
Elongation at Break
3.4 %
DAM; ISO 527-1/-2
5.0 %
50% RH; ISO 527-1/-2
Tensile Modulus
7000
MPa
50% RH; ISO 527-1/-2
10000
MPa
DAM; ISO 527-1/-2
Flexural Strength
200
MPa
50% RH; ISO 178
280
MPa
DAM; ISO 178
Flexural Modulus
6.30
GPa
50% RH; ISO 178
9.00
GPa
DAM; ISO 178
Poissons Ratio
0.34
DAM; ISO 527-1/-2
0.35
50%RH; ISO 527-1/-2
Izod Impact, Unnotched (ISO)
10.0
kJ/m²
@Temperature -30.0 °C
50% RH; ISO 180/1A
12.0
kJ/m²
@Temperature -30.0 °C
DAM; ISO 180/1A
13.0
kJ/m²
@Temperature 23.0 °C
DAM; ISO 180/1A
17.0
kJ/m²
@Temperature 23.0 °C
50% RH; ISO 180/1A
Charpy Impact Unnotched
70.0
kJ/m²
@Temperature -30.0 °C
DAM; ISO 179/1eU
73.0
kJ/m²
@Temperature -30.0 °C
50% RH; ISO 179/1eU
82.0
kJ/m²
@Temperature 23.0 °C
DAM; ISO 179/1eU
93.0
kJ/m²
@Temperature 23.0 °C
50% RH; ISO 179/1eU
Charpy Impact, Notched
10.0
kJ/m²
@Temperature -30.0 °C
50% RH; ISO 179/1eA
10.0
kJ/m²
@Temperature -30.0 °C
DAM; ISO 179/1eA
12.0
kJ/m²
@Temperature 23.0 °C
DAM; ISO 179/1eA
16.0
kJ/m²
@Temperature 23.0 °C
50% RH; ISO 179/1eA
Tensile Creep Modulus, 1 hour
6800
MPa
50% RH; ISO 899-1
Tensile Creep Modulus, 1000 hours
5100
MPa
50% RH; ISO 899-1
Electrical Properties
Original Value
Comments
Volume Resistivity
1.00e+11
ohm-cm
50% RH; IEC 62631-3-1
>=
1.00e+15
ohm-cm
DAM; IEC 62631-3-1
Surface Resistance
1.00e+13
ohm
50% RH; IEC 62631-3-2
Dielectric Constant
4.1
@Frequency 1e+6 Hz
DAM; IEC 62631-2-1
4.4
@Frequency 100 Hz
DAM; IEC 62631-2-1
4.6
@Frequency 1e+6 Hz
50% RH; IEC 62631-2-1
10.8
@Frequency 100 Hz
50% RH; IEC 62631-2-1
Dielectric Strength
32.0
kV/mm
50% RH; IEC 60243-1
38.0
kV/mm
DAM; IEC 60243-1
Dissipation Factor
0.0070
@Frequency 100 Hz
DAM; IEC 62631-2-1
0.015
@Frequency 1e+6 Hz
DAM; IEC 62631-2-1
0.065
@Frequency 1e+6 Hz
50% RH; IEC 62631-2-1
0.46
@Frequency 100 Hz
50% RH; IEC 62631-2-1
Comparative Tracking Index
400
V
DAM; IEC 60112
Thermal Properties
Original Value
Comments
CTE, linear, Parallel to Flow
22.0
µm/m-°C
DAM; ISO 11359-1/-2
CTE, linear, Transverse to Flow
107
µm/m-°C
DAM; ISO 11359-1/-2
Melting Point
263
°C
10°C/min; DAM; ISO 11357-1/-3
Deflection Temperature at 0.46 MPa (66 psi)
261
°C
DAM; ISO 75-1/-2
Deflection Temperature at 1.8 MPa (264 psi)
248
°C
DAM; ISO 75-1/-2
Glass Transition Temp, Tg
20.0
°C
10°C/min; 50% RH; ISO 11357-1/-2
80.0
°C
10°C/min; DAM; ISO 11357-1/-2
Flammability, UL94
HB
@Thickness 0.750 mm
DAM; IEC 60695-11-10
HB
@Thickness 1.50 mm
DAM; IEC 60695-11-10
Flame Spread
13.0
mm/min
@Thickness 1.00 mm
ISO 3795 (FMVSS 302)
Oxygen Index
24 %
DAM; ISO 4589-1/-2
Processing Properties
Original Value
Comments
Melt Temperature
285
-
305
°C
Injection
295
°C
Injection Optimum
Mold Temperature
70.0
-
120
°C
Injection
100
°C
Injection Optimum
Ejection Temperature
210
°C
Injection
Drying Temperature
80.0
°C
Injection
Dry Time
2.00
-
4.00
hour
Dehumidified Dryer; Injection
Moisture Content
0.20 %
Injection
Hold Pressure
50.0
-
100
MPa
Injection
Descriptive Properties
Drying Recommended
yes
Injection
Emission of organic compounds
6 µgC/g
VDA 277
FMVSS Class
B
ISO 3795 (FMVSS 302)
Fogging F-value (refraction) (%)
95
ISO 6452; DAM
Fogging G-value (condensate) (mg)
0.3
ISO 6452; DAM
Hold pressure time (s/mm)
3
Injection
Max. screw tangential speed (m/s)
0.2
Injection
Odor
4.5
VDA 270
Part Marking Code
PA66-GF30
ISO 11469
Processing
Injection Molding
Regional Availability
Europe
Near East/Africa
Resin Identification
PA66-GF30
ISO 1043
Special characteristics
Heat stabilized or stable to heat
**
Materials flagged as discontinued (
) are no longer part of the manufacturer’s standard product line according to our latest information. These materials may be available by special order, in distribution inventory, or reinstated as an active product. Data sheets from materials that are no longer available remain in MatWeb to assist users in finding replacement materials.
Users of our Advanced Search (registration required) may exclude discontinued materials from search results.
Some of the values displayed above may have been converted from their original units and/or rounded in order to display the information in a consistent format. Users requiring more precise data for scientific or engineering calculations can click on the property value to see the original value as well as raw conversions to equivalent units. We advise that you only use the original value or one of its raw conversions in your calculations to minimize rounding error. We also ask that you refer to MatWeb's
terms of use
regarding this information.
Click here
to go back to viewing the property data in MatWeb's normal format.
Users viewing this material also viewed the following:
DuPont Mobility and Materials Zytel® 70G30HSL BK039B PA66-GF30
Celanese Zytel® 70G30HSLR BK099 PA66-GF30
Celanese Zytel® 70G30HSLR NC010 PA66-GF30
Celanese Zytel® 70G30L NC010 PA66-GF30
Celanese Zytel® 103HSL NC010 PA66
PDSX5324 / 197964
Subscribe to Premium Services
Searches:
Advanced
•
Composition
•
Property
•
Material Type
•
Manufacturer
•
Trade Name
•
UNS Number
Other Links:
Advertising
•
Submit Data
•
Database Licensing
•
Web Design & Hosting
•
Trade Publications
Supplier List
•
Unit Converter
•
Reference
•
Links
•
Help
•
Contact Us
•
Site Map
•
FAQ
•
Home
Follow @MatWeb
Please read our
License Agreement
regarding materials data and our
Privacy Policy
. Questions or comments about MatWeb? Please contact us at
info@matweb.com
. We appreciate your input.
The contents of this web site, the MatWeb logo, and "MatWeb" are Copyright 1996-2025 by MatWeb, LLC. MatWeb is intended for personal, non-commercial use. The contents, results, and technical data from this site may not be reproduced either electronically, photographically or substantively without permission from MatWeb, LLC.