USP Class VI Adhesives
USP Class VI Approved Adhesives for Medical Device Applications
Master Bond’s biocompatible adhesives are designed to meet the needs of medical device manufacturers. Compounds withstand various types of sterilization methods.

(Viewing data as-entered. Click here to return)
Master Bond MB270NT Ethyl Cyanoacrylate
Categories: Polymer; Adhesive; Thermoset; Acrylic/Cyanoacrylate Adhesive

Material Notes: Key Features:
  • Non-toxic as per ISO 10993-5
  • One component, no mix system
  • Rapid fixture time
  • Fast setting
Product Description: Master Bond MB270NT is a single component, high viscosity ethyl cyanoacrylate type system. The system cures briskly and is used primarily in applications where ISO 10993-5 for cytotoxicity is specified. Typically, cyanoacrylates have lower viscosities and once in a while they can be a gel. On the other hand, MB270NT, with a viscosity range of 25,000-30,000 cps, is certainly out of the ordinary. Cyanoacrylates are commonly referred to as super glues or instant adhesives. Their curing is dependent upon the humidity with the higher the level, the faster the rate of cure. Since the cure is fast, only minimal contact pressure is required for bonding. There is no mixing or heating required for curing. Depending upon the humidity and the substrates, MB270NT will typically set up within 30-75 seconds. Cyanoacrylates have limitations in their ability to fill gaps, with most commonly used systems, having gap filling capabilities up to 0.01-0.015 inches. MB270NT has improved performance in this regard, and depending upon the application, it can fill gaps up to 0.03-0.04 inches thick. MB270NT bonds well to a variety of substrates especially plastics, metals, rubbers and composites, especially in the shear mode. The service temperature range for this system is -60°F to +250°F. MB270NT can be used in a wide array of different applications ranging from repair to high speed production in which the ISO specification is required. It is highly resistant to EtO and gamma sterilization. Although many of the applications for MB270NT involve disposable type medical devices, it also can be utilized with reusable ones depending upon the service conditions.

Product Advantages:

  • No heating or mixing
  • Rapid curing at room temperature; usually sets up within 30-75 seconds
  • Contact pressure usually sufficient for fixturing
  • Bonds well to a wide variety of substrates
  • Excellent resistance to EtO and gamma sterilization
  • Can be used in disposable and reusable medical devices
  • Passes ISO 10993-5

Information provided by Master Bond Inc.

Vendors: Master Bond is a leading manufacturer of adhesives, sealants, coatings and potting compounds. Master Bond’s vast product line consists of over 3,000 epoxy, polyurethane, silicone, cyanoacrylate and latex adhesives that vary in viscosity, cure speed, strength, chemical resistance, electrical properties, etc. Our custom adhesives offer design flexibility and provide excellent bonding performance. Visit www.masterbond.com.

Click here to view all available suppliers for this material.

Please click here if you are a supplier and would like information on how to add your listing to this material.

 
Physical PropertiesOriginal ValueComments
Specific Gravity 1.05 g/cc
Viscosity 25000 - 30000 cP
 
Mechanical PropertiesOriginal ValueComments
Hardness, Shore D 70
Tensile Strength 6000 psi
Elongation at Break 2.0 - 3.0 %
Tensile Modulus 225000 - 275000 psi
Adhesive Bond Strength 210 psiButyl-Butyl, Tensile lap; Substrate Failure
 300 psiSteel-Natural Rubber, Tensile lap; Substrate Failure
 350 psiSteel-Butyl, Tensile lap; Substrate Failure
 420 psiNatural Rubber-Natural Rubber, Tensile lap; Substrate Failure
 440 psiSBR-SBR, Tensile lap; Substrate Failure
 490 psiNeoprene-Steel, Tensile lap
 510 psiNBR-NBR, Tensile lap; Substrate Failure
 510 psiNitrile-Nitrile, Tensile lap; Substrate Failure
 520 psiNeoprene-Neoprene, Tensile lap; Substrate Failure
 570 psiPolystyrene-Polystyrene, Tensile lap; Substrate Failure
 900 psiDelrin-Delrin, Tensile lap
 940 psiNylon-Bakelite, Tensile lap
 970 psiNylon-Nylon, Tensile lap
 980 psiNBR-Aluminum, Tensile lap
 1090 psiChromium-Chromium, Tensile lap
 1200 psiAluminum-Aluminum, Tensile lap
 1260 psiPhenolic-Phenolic, Tensile lap
 1300 psiABS-ABS, Tensile lap
 1410 psiNylon-Copper, Tensile lap; Substrate Failure
 1600 psiAluminum-Stainless Steel, Tensile lap
 1680 psiSteel-Stainless Steel, Tensile lap
 2050 psiSteel-PVC (rigid), Tensile lap; Substrate Failure
 2200 psiPolyester-Polyester, Tensile lap
 2350 psiSteel-Aluminum, Tensile lap
 2380 psiStainless-Stainless, Tensile lap
 2400 psiBrass-Brass, Tensile lap
 2410 psiCopper-Copper, Tensile lap
 2430 psiSteel-Steel, Tensile lap
 2670 psiPVC(rigid)-PVC(rigid), Tensile lap; Substrate Failure
 
Electrical PropertiesOriginal ValueComments
Volume Resistivity >= 1.00e+15 ohm-cm
Dielectric Constant 3.6
@Frequency 1000 Hz
 
Thermal PropertiesOriginal ValueComments
CTE, linear 70.0 - 75.0 µm/m-°C
Maximum Service Temperature, Air 250 °F
Softening Point 290 - 300 °F
Minimum Service Temperature, Air -60.0 °F
 
Processing PropertiesOriginal ValueComments
Cure Time 0.500 - 1.25 minset up time, substrate dependent
Shelf Life 6.00 Month
@Temperature 4.44 - 10.0 °C
in original, unopened containers
 
Descriptive Properties
ColorColorless, transparent liquid

Some of the values displayed above may have been converted from their original units and/or rounded in order to display the information in a consistent format. Users requiring more precise data for scientific or engineering calculations can click on the property value to see the original value as well as raw conversions to equivalent units. We advise that you only use the original value or one of its raw conversions in your calculations to minimize rounding error. We also ask that you refer to MatWeb's terms of use regarding this information. Click here to go back to viewing the property data in MatWeb's normal format.

Users viewing this material also viewed the following:
Covestro Texin® 270 Thermoplastic Polyurethanes (TPU)
Elastomer Engineering E57L Polyurethane
DuPont Mobility and Materials Delrin® 570 NC000 POM-GF20
Covestro Texin® 260 Thermoplastic Polyurethanes (TPU)
Celanese Hostaform® C 9021 10/1570 POM, Specialty

PMASTM921 / 185514

USP Class VI adhesives

Please read our License Agreement regarding materials data and our Privacy Policy. Questions or comments about MatWeb? Please contact us at webmaster@matweb.com. We appreciate your input.

The contents of this web site, the MatWeb logo, and "MatWeb" are Copyright 1996-2024 by MatWeb, LLC. MatWeb is intended for personal, non-commercial use. The contents, results, and technical data from this site may not be reproduced either electronically, photographically or substantively without permission from MatWeb, LLC.