Ensinger PEI

(Viewing data as-entered. Click here to return)
Akro-Plastic Akromid® B3 1 FR black (6580) Nylon 6, Flame Retardant
Categories: Polymer; Thermoplastic; Nylon (Polyamide PA); Nylon 6 (PA6); Nylon 6, Unreinforced, Flame Retardant

Material Notes: Flame Retardant Compound. V0 at 0.4 mm with good strength. PA 6 FR (30)

Information provided by Akro-Plastic GmbH

Vendors: No vendors are listed for this material. Please click here if you are a supplier and would like information on how to add your listing to this material.
 
Physical PropertiesOriginal ValueComments
Density 1.19 g/ccISO 1183
Linear Mold Shrinkage, Flow 0.0090 - 0.011 cm/cmISO 294-4
Linear Mold Shrinkage, Transverse 0.010 - 0.012 cm/cmISO 294-4
 
Mechanical PropertiesOriginal ValueComments
Tensile Strength, Yield 40.0 MPa5 mm/min. Conditioned; ISO 527-2
 75.0 MPa5 mm/min. Dry as Molded; ISO 527-2
Elongation at Break >= 10 %5 mm/min. Dry as Molded; ISO 527-2
 >= 50 %5 mm/min. Conditioned; ISO 527-2
Tensile Modulus 1300 MPa1 mm/min. Conditioned; ISO 527-2
 3600 MPa1 mm/min. Dry as Molded.; ISO 527-2
Flexural Strength 45.0 MPaConditioned. 2 mm/min; ISO 178
 115 MPaDry as Molded. 2 mm/min; ISO 178
Flexural Modulus 1300 MPa2 mm/min. Conditioned; ISO 178
 3500 MPa2 mm/min. Dry as Molded; ISO 178
Charpy Impact Unnotched 78.0 kJ/m²
@Temperature 23.0 °C
Dry as Molded; ISO 179-1/1eA
Charpy Impact, Notched 4.50 kJ/m²
@Temperature 23.0 °C
Dry as Molded; ISO 179-1/1eA
 13.0 kJ/m²
@Temperature 23.0 °C
Conditioned; ISO 179-1/1eA
 
Electrical PropertiesOriginal ValueComments
Dielectric Strength 10.0 kV/mm
@Thickness 1.00 mm
Conditioned; IEC 60243
 10.0 kV/mm
@Thickness 1.00 mm
Dry as Molded; IEC 60243
Comparative Tracking Index >= 600 VDry as Molded. Test solution A; IEC 60112
Hot Wire Ignition, HWI 7.0 - 15 sec
@Thickness 0.400 mm
Dry as Molded; UL 746A
 7.0 - 15 sec
@Thickness 0.800 mm
Conditioned; UL 746A
 7.0 - 15 sec
@Thickness 0.400 mm
Conditioned; UL 746A
 7.0 - 15 sec
@Thickness 0.800 mm
Dry as Molded; UL 746A
 >= 120 sec
@Thickness 1.60 mm
Conditioned; UL 746A
 >= 120 sec
@Thickness 3.20 mm
Conditioned; UL 746A
 >= 120 sec
@Thickness 1.60 mm
Dry as Molded; UL 746A
 >= 120 sec
@Thickness 3.20 mm
Dry as Molded; UL 746A
High Amp Arc Ignition, HAI >= 120 arcs
@Thickness 0.400 mm
Conditioned; UL 746A
 >= 120 arcs
@Thickness 0.800 mm
Conditioned; UL 746A
 >= 120 arcs
@Thickness 1.60 mm
Conditioned; UL 746A
 >= 120 arcs
@Thickness 3.20 mm
Conditioned; UL 746A
 >= 120 arcs
@Thickness 0.400 mm
Dry as Molded; UL 746A
 >= 120 arcs
@Thickness 0.800 mm
Dry as Molded; UL 746A
 >= 120 arcs
@Thickness 1.60 mm
Dry as Molded; UL 746A
 >= 120 arcs
@Thickness 3.20 mm
Dry as Molded; UL 746A
 
Thermal PropertiesOriginal ValueComments
Melting Point 220 °CDry as Molded. DES, 10°C/min; DIN EN 11357-1
Deflection Temperature at 0.46 MPa (66 psi) 180 °CDry as Molded; ISO 75
Deflection Temperature at 1.8 MPa (264 psi) 60.0 °CDry as Molded; ISO 75
UL RTI, Electrical 65.0 °C
@Thickness 0.400 mm
Conditioned; UL 746 B
 65.0 °C
@Thickness 0.800 mm
Conditioned; UL 746 B
 65.0 °C
@Thickness 1.60 mm
Conditioned; UL 746 B
 65.0 °C
@Thickness 3.20 mm
Conditioned; UL 746 B
 65.0 °C
@Thickness 0.400 mm
Dry as Molded; UL 746 B
 65.0 °C
@Thickness 0.800 mm
Dry as Molded; UL 746 B
 65.0 °C
@Thickness 1.60 mm
Dry as Molded; UL 746 B
 65.0 °C
@Thickness 3.20 mm
Dry as Molded; UL 746 B
UL RTI, Mechanical with Impact 65.0 °C
@Thickness 0.400 mm
Conditioned; UL 746 B
 65.0 °C
@Thickness 0.800 mm
Conditioned; UL 746 B
 65.0 °C
@Thickness 1.60 mm
Conditioned; UL 746 B
 65.0 °C
@Thickness 3.20 mm
Conditioned; UL 746 B
 65.0 °C
@Thickness 0.400 mm
Dry as Molded; UL 746 B
 65.0 °C
@Thickness 0.800 mm
Dry as Molded; UL 746 B
 65.0 °C
@Thickness 1.60 mm
Dry as Molded; UL 746 B
 65.0 °C
@Thickness 3.20 mm
Dry as Molded; UL 746 B
UL RTI, Mechanical without Impact 65.0 °C
@Thickness 0.400 mm
Conditioned; UL 746 B
 65.0 °C
@Thickness 0.800 mm
Conditioned; UL 746 B
 65.0 °C
@Thickness 1.60 mm
Conditioned; UL 746 B
 65.0 °C
@Thickness 3.20 mm
Conditioned; UL 746 B
 65.0 °C
@Thickness 0.400 mm
Dry as Molded; UL 746 B
 65.0 °C
@Thickness 0.800 mm
Dry as Molded; UL 746 B
 65.0 °C
@Thickness 1.60 mm
Dry as Molded; UL 746 B
 65.0 °C
@Thickness 3.20 mm
Dry as Molded; UL 746 B
Flammability, UL94 V-0
@Thickness 0.800 mm
Conditioned
 V-0
@Thickness 0.400 mm
Conditioned
 V-0
@Thickness 1.60 mm
Conditioned
 V-0
@Thickness 3.20 mm
Conditioned
 V-0
@Thickness 0.400 mm
Dry as Molded
 V-0
@Thickness 1.60 mm
Dry as Molded
 V-0
@Thickness 3.20 mm
Dry as Molded
 V-0
@Thickness 0.800 mm
Dry as Molded
Oxygen Index >= 32 %Conditioned; ISO 4589-1/2
 >= 32 %Dry as Molded; ISO 4589-1/2
Glow Wire Ignition Temperature 750 °C
@Thickness 0.800 mm
Dry as Molded; IEC 60695-2-13
 750 °C
@Thickness 1.60 mm
Dry as Molded; IEC 60695-2-13
 750 °C
@Thickness 3.20 mm
Dry as Molded; IEC 60695-2-13
 750 °C
@Thickness 0.800 mm
Conditioned; IEC 60695-2-13
 750 °C
@Thickness 1.60 mm
Conditioned; IEC 60695-2-13
 750 °C
@Thickness 3.20 mm
Conditioned; IEC 60695-2-13
 775 °C
@Thickness 0.400 mm
Conditioned; IEC 60695-2-13
 775 °C
@Thickness 0.400 mm
Dry as Molded; IEC 60695-2-13
Glow Wire Flammability Index 960 °C
@Thickness 0.400 mm
Conditioned; IEC 60695-2-12
 960 °C
@Thickness 0.800 mm
Conditioned; IEC 60695-2-12
 960 °C
@Thickness 1.60 mm
Conditioned; IEC 60695-2-12
 960 °C
@Thickness 3.20 mm
Conditioned; IEC 60695-2-12
 960 °C
@Thickness 0.400 mm
Dry as Molded; IEC 60695-2-12
 960 °C
@Thickness 0.800 mm
Dry as Molded; IEC 60695-2-12
 960 °C
@Thickness 1.60 mm
Dry as Molded; IEC 60695-2-12
 960 °C
@Thickness 3.20 mm
Dry as Molded; IEC 60695-2-12
 
Descriptive Properties
Railway Requirement SetsR22/23/24/26 HL3EN 45545-2. Dry as Molded
 R22/23/24/26 HL3EN 45545-2. Conditioned

Some of the values displayed above may have been converted from their original units and/or rounded in order to display the information in a consistent format. Users requiring more precise data for scientific or engineering calculations can click on the property value to see the original value as well as raw conversions to equivalent units. We advise that you only use the original value or one of its raw conversions in your calculations to minimize rounding error. We also ask that you refer to MatWeb's terms of use regarding this information. Click here to go back to viewing the property data in MatWeb's normal format.

PAKRO9927 / 255584

Proto3000 – 3D Engineering Solutions

Please read our License Agreement regarding materials data and our Privacy Policy. Questions or comments about MatWeb? Please contact us at webmaster@matweb.com. We appreciate your input.

The contents of this web site, the MatWeb logo, and "MatWeb" are Copyright 1996-2024 by MatWeb, LLC. MatWeb is intended for personal, non-commercial use. The contents, results, and technical data from this site may not be reproduced either electronically, photographically or substantively without permission from MatWeb, LLC.