Ascend Performance Materials Vydyne® 41HFE BL0887 PA66-I-MED(x)
Categories: Polymer; Thermoplastic; Nylon (Polyamide PA); Nylon 66 (PA66); Nylon 66, Heat Stabilized

Material Notes: Vydyne 41HFE BL0887 is a high impact modified, metal and x-ray detectable, heat stabilized PA66. This resin imparts good toughness and impact resistance while offering metal and x-ray detectability in critical applications.

Information provided by Ascend Performance Materials.

Vendors: No vendors are listed for this material. Please click here if you are a supplier and would like information on how to add your listing to this material.
 
Physical PropertiesMetricEnglishComments
Density 1.32 g/cc0.0477 lb/in³DAM; ISO 1183
Water Absorption 1.1 %
@Temperature 23.0 °C,
Time 86400 sec
1.1 %
@Temperature 73.4 °F,
Time 24.0 hour
DAM; ISO 62
Moisture Absorption at Equilibrium 1.1 %1.1 %DAM to 50% RH; ISO 62
Linear Mold Shrinkage, Flow 0.0080 cm/cm
@Thickness 2.00 mm
0.0080 in/in
@Thickness 0.0787 in
DAM; ISO 294-4
Linear Mold Shrinkage, Transverse 0.011 cm/cm
@Thickness 2.00 mm
0.011 in/in
@Thickness 0.0787 in
DAM; ISO 294-4
 
Mechanical PropertiesMetricEnglishComments
Tensile Strength at Break 32.0 MPa4640 psi50% RH; ISO 527-2
 38.0 MPa5510 psiDAM; ISO 527-2
Elongation at Break 33 %33 %DAM; ISO 527-2
 >= 50 %>= 50 %50% RH; ISO 527-2
Tensile Modulus 0.800 GPa116 ksi50% RH; ISO 527-2
 1.70 GPa247 ksiDAM; ISO 527-2
Flexural Strength 18.0 MPa2610 psi50% RH; ISO 178
 45.0 MPa6530 psiDAM; ISO 178
Flexural Modulus 0.800 GPa116 ksi50% RH; ISO 178
 1.80 GPa261 ksiDAM; ISO 178
Izod Impact, Notched (ISO)  13.0 kJ/m²
@Temperature -40.0 °C
6.19 ft-lb/in²
@Temperature -40.0 °F
DAM; ISO 180/1A
 13.0 kJ/m²
@Temperature -30.0 °C
6.19 ft-lb/in²
@Temperature -22.0 °F
DAM; ISO 180/1A
 15.0 kJ/m²
@Temperature -40.0 °C
7.14 ft-lb/in²
@Temperature -40.0 °F
50% RH; ISO 180/1A
 15.0 kJ/m²
@Temperature -30.0 °C
7.14 ft-lb/in²
@Temperature -22.0 °F
50% RH; ISO 180/1A
 22.0 kJ/m²
@Temperature 23.0 °C
10.5 ft-lb/in²
@Temperature 73.4 °F
DAM; ISO 180/1A
 52.0 kJ/m²
@Temperature 23.0 °C
24.7 ft-lb/in²
@Temperature 73.4 °F
50% RH; ISO 180/1A
Charpy Impact Unnotched  NB
@Temperature -40.0 °C
NB
@Temperature -40.0 °F
DAM; ISO 179/1eU
 NB
@Temperature -40.0 °C
NB
@Temperature -40.0 °F
50% RH; ISO 179/1eU
 NB
@Temperature -30.0 °C
NB
@Temperature -22.0 °F
DAM; ISO 179/1eU
 NB
@Temperature -30.0 °C
NB
@Temperature -22.0 °F
50% RH; ISO 179/1eU
 NB
@Temperature 23.0 °C
NB
@Temperature 73.4 °F
DAM; ISO 179/1eU
 NB
@Temperature 23.0 °C
NB
@Temperature 73.4 °F
50% RH; ISO 179/1eU
Charpy Impact, Notched  1.10 J/cm²
@Temperature -40.0 °C
5.23 ft-lb/in²
@Temperature -40.0 °F
50% RH; ISO 179/1eA
 1.20 J/cm²
@Temperature -30.0 °C
5.71 ft-lb/in²
@Temperature -22.0 °F
50% RH; ISO 179/1eA
 1.30 J/cm²
@Temperature -40.0 °C
6.19 ft-lb/in²
@Temperature -40.0 °F
DAM; ISO 179/1eA
 1.30 J/cm²
@Temperature -30.0 °C
6.19 ft-lb/in²
@Temperature -22.0 °F
DAM; ISO 179/1eA
 2.50 J/cm²
@Temperature 23.0 °C
11.9 ft-lb/in²
@Temperature 73.4 °F
DAM; ISO 179/1eA
 4.70 J/cm²
@Temperature 23.0 °C
22.4 ft-lb/in²
@Temperature 73.4 °F
50% RH; ISO 179/1eA
 
Electrical PropertiesMetricEnglishComments
Dielectric Strength  23.0 kV/mm
@Thickness 1.00 mm
584 kV/in
@Thickness 0.0394 in
50% RH; IEC 60243
 25.0 kV/mm
@Thickness 1.00 mm
635 kV/in
@Thickness 0.0394 in
DAM; IEC 60243
 
Thermal PropertiesMetricEnglishComments
Melting Point 260 °C500 °FDAM; ISO 11357-3
Deflection Temperature at 0.46 MPa (66 psi) 115 °C239 °FUnannealed, DAM; ISO 75-2/B
 152 °C306 °FUnannealed, 50% RH; ISO 75-2/B
Deflection Temperature at 1.8 MPa (264 psi) 53.0 °C127 °FUnannealed, 50% RH; ISO 75-2/A
 57.0 °C135 °FUnannealed, DAM; ISO 75-2/A
 
Processing PropertiesMetricEnglishComments
Rear Barrel Temperature 280 - 310 °C536 - 590 °FInjection
Middle Barrel Temperature 280 - 310 °C536 - 590 °FInjection
Front Barrel Temperature 280 - 310 °C536 - 590 °FInjection
Nozzle Temperature 280 - 310 °C536 - 590 °FInjection
Melt Temperature 285 - 305 °C545 - 581 °FInjection
Mold Temperature 65.0 - 95.0 °C149 - 203 °FInjection
Drying Temperature 80.0 °C176 °F
Dry Time 4.00 hour4.00 hour
 
Descriptive Properties
AdditiveHeat Stabilizer
 Lubricant
 Release agent
Agency RatingsASTM, D4066 PA0160B2362
 ASTM, D6779 PA0160B2362
 ISO, 1043 PA66 MED(x)
 SAE, J1639 PA0172
AppearanceBlue
FeaturesHeat Stabilized
 High Impact Resistance
 Lubricated
FormsPellets
Processing MethodInjection Molding
RegionNorth America, Europe, Asia Pacific, South and Central America, Near East/Africa

Some of the values displayed above may have been converted from their original units and/or rounded in order to display the information in a consistent format. Users requiring more precise data for scientific or engineering calculations can click on the property value to see the original value as well as raw conversions to equivalent units. We advise that you only use the original value or one of its raw conversions in your calculations to minimize rounding error. We also ask that you refer to MatWeb's terms of use regarding this information. Click here to view all the property values for this datasheet as they were originally entered into MatWeb.

PASCE8483 / 320954

Specialty Compounds RTP Company

Please read our License Agreement regarding materials data and our Privacy Policy. Questions or comments about MatWeb? Please contact us at webmaster@matweb.com. We appreciate your input.

The contents of this web site, the MatWeb logo, and "MatWeb" are Copyright 1996-2024 by MatWeb, LLC. MatWeb is intended for personal, non-commercial use. The contents, results, and technical data from this site may not be reproduced either electronically, photographically or substantively without permission from MatWeb, LLC.