Ensinger PEI

Envalior ForTii® JTX2 PPA-GF30 PA4T High Temperature Polyamide
Categories: Polymer; Thermoplastic; Polyphthalamide (PPA); Polyphthalamide (PPA), 30% Glass Fiber Reinforced

Material Notes: ForTii® is a high temperature polyamide for applications in the electronics, lighting, automotive, white goods, industrial and aerospace industries.

ForTii® JTX2 has robust mechanical performance and has good reliability in thermal ageing and mechanical shocks. JTX2 has consistent performance in injection molding processing and a low risk of blistering due to its JEDEC MLS 1 rating for specified thicknesses. JTX2 is the best candidate for HB reflow headers/connectors in (automotive) electronics. Processing: Injection molding. 30% glass reinforced.

Former DSM Engineering Plastics product line is now with Envalior.

Vendors: No vendors are listed for this material. Please click here if you are a supplier and would like information on how to add your listing to this material.
 
Physical PropertiesMetricEnglishComments
Density 1.43 g/cc0.0517 lb/in³Dry; ISO 1183
Moisture Absorption 2.00 %2.00 %Dry; Sim. to ISO 62
Linear Mold Shrinkage, Flow 0.0040 cm/cm0.0040 in/inDry; ISO 294-4
Linear Mold Shrinkage, Transverse 0.012 cm/cm0.012 in/inDry; ISO 294-4
 
Mechanical PropertiesMetricEnglishComments
Tensile Strength at Break  75.0 MPa
@Temperature 200 °C
10900 psi
@Temperature 392 °F
ISO 527-1/-2
 90.0 MPa
@Temperature 160 °C
13100 psi
@Temperature 320 °F
ISO 527-1/-2
 95.0 MPa
@Temperature 80.0 °C
13800 psi
@Temperature 176 °F
Cond; ISO 527-1/-2
 135 MPa
@Temperature 120 °C
19600 psi
@Temperature 248 °F
Dry; ISO 527-1/-2
 180 MPa
@Temperature 23.0 °C
26100 psi
@Temperature 73.4 °F
Cond; ISO 527-1/-2
 180 MPa
@Temperature 80.0 °C
26100 psi
@Temperature 176 °F
Dry; ISO 527-1/-2
 200 MPa
@Temperature 23.0 °C
29000 psi
@Temperature 73.4 °F
Dry; ISO 527-1/-2
Elongation at Break  2.0 %
@Temperature 23.0 °C
2.0 %
@Temperature 73.4 °F
Cond; ISO 527-1/-2
 2.2 %
@Temperature 23.0 °C
2.2 %
@Temperature 73.4 °F
Dry; ISO 527-1/-2
 2.6 %
@Temperature 80.0 °C
2.6 %
@Temperature 176 °F
Dry; ISO 527-1/-2
 6.0 %
@Temperature 80.0 °C
6.0 %
@Temperature 176 °F
Cond; ISO 527-1/-2
 6.0 %
@Temperature 160 °C
6.0 %
@Temperature 320 °F
ISO 527-1/-2
 6.0 %
@Temperature 200 °C
6.0 %
@Temperature 392 °F
ISO 527-1/-2
Tensile Modulus  0.400 GPa
@Temperature 200 °C
58.0 ksi
@Temperature 392 °F
ISO 527-1/-2
 4.50 GPa
@Temperature 160 °C
653 ksi
@Temperature 320 °F
ISO 527-1/-2
 6.20 GPa
@Temperature 80.0 °C
899 ksi
@Temperature 176 °F
Cond; ISO 527-1/-2
 8.00 GPa
@Temperature 120 °C
1160 ksi
@Temperature 248 °F
Dry; ISO 527-1/-2
 10.5 GPa
@Temperature 80.0 °C
1520 ksi
@Temperature 176 °F
Dry; ISO 527-1/-2
 11.3 GPa
@Temperature 23.0 °C
1640 ksi
@Temperature 73.4 °F
Dry; ISO 527-1/-2
 11.5 GPa
@Temperature 23.0 °C
1670 ksi
@Temperature 73.4 °F
Cond; ISO 527-1/-2
Flexural Strength 270 MPa39200 psiCond; ISO 178
 300 MPa43500 psiDry; ISO 178
Flexural Modulus  4.00 GPa
@Temperature 200 °C
580 ksi
@Temperature 392 °F
ISO 178
 4.50 GPa
@Temperature 160 °C
653 ksi
@Temperature 320 °F
ISO 178
 7.50 GPa
@Temperature 120 °C
1090 ksi
@Temperature 248 °F
ISO 178
 10.5 GPa
@Temperature 23.0 °C
1520 ksi
@Temperature 73.4 °F
Dry; ISO 178
 11.0 GPa
@Temperature 23.0 °C
1600 ksi
@Temperature 73.4 °F
Cond; ISO 178
Charpy Impact Unnotched  4.50 J/cm²
@Temperature -30.0 °C
21.4 ft-lb/in²
@Temperature -22.0 °F
Cond; ISO 179/1eU
 5.00 J/cm²
@Temperature 23.0 °C
23.8 ft-lb/in²
@Temperature 73.4 °F
Cond; ISO 179/1eU
 5.50 J/cm²
@Temperature -30.0 °C
26.2 ft-lb/in²
@Temperature -22.0 °F
Dry; ISO 179/1eU
 6.00 J/cm²
@Temperature 23.0 °C
28.6 ft-lb/in²
@Temperature 73.4 °F
Dry; ISO 179/1eU
Charpy Impact, Notched  0.900 J/cm²
@Temperature 23.0 °C
4.28 ft-lb/in²
@Temperature 73.4 °F
Cond; ISO 179/1eA
 0.900 J/cm²
@Temperature -30.0 °C
4.28 ft-lb/in²
@Temperature -22.0 °F
Cond; ISO 179/1eA
 1.00 J/cm²
@Temperature 23.0 °C
4.76 ft-lb/in²
@Temperature 73.4 °F
Dry; ISO 179/1eA
 1.00 J/cm²
@Temperature -30.0 °C
4.76 ft-lb/in²
@Temperature -22.0 °F
Dry; ISO 179/1eA
 
Electrical PropertiesMetricEnglishComments
Volume Resistivity >= 1.00e+13 ohm-cm>= 1.00e+13 ohm-cmDry; IEC 60093
 >= 1.00e+13 ohm-cm>= 1.00e+13 ohm-cmCond; IEC 60093
Dielectric Constant  3.8
@Frequency 1e+10 Hz
3.8
@Frequency 1e+10 Hz
Dry; IEC 60250
 3.9
@Frequency 1e+9 Hz
3.9
@Frequency 1e+9 Hz
Dry; IEC 60250
 3.9
@Frequency 1e+10 Hz
3.9
@Frequency 1e+10 Hz
Cond; IEC 60250
 4.0
@Frequency 1e+9 Hz
4.0
@Frequency 1e+9 Hz
Cond; IEC 60250
 4.5
@Frequency 1e+6 Hz
4.5
@Frequency 1e+6 Hz
Dry; IEC 62631-2-1
 4.5
@Frequency 1e+6 Hz
4.5
@Frequency 1e+6 Hz
Cond; IEC 62631-2-1
 5.0
@Frequency 100 Hz
5.0
@Frequency 100 Hz
Dry; IEC 62631-2-1
 5.0
@Frequency 100 Hz
5.0
@Frequency 100 Hz
Cond; IEC 62631-2-1
Dielectric Strength 40.0 kV/mm1020 kV/inCond; IEC 60243-1
 43.0 kV/mm1090 kV/inDry; IEC 60243-1
Comparative Tracking Index 600 V600 VIEC 60112
 
Thermal PropertiesMetricEnglishComments
CTE, linear 40.0 µm/m-°C22.2 µin/in-°FISO 11359-1/-2
CTE, linear, Parallel to Flow 33.0 µm/m-°C18.3 µin/in-°FISO 11359-1/-2
Melting Point 325 °C617 °F10°C/min. Dry; ISO 11357-1/-3
Maximum Service Temperature, Air 167 °C333 °FThermal Index; 5000 hrs.; IEC 60216/ISO 527-1/-2
Deflection Temperature at 1.8 MPa (264 psi) 305 °C581 °FDry; ISO 75-1/-2
Flammability, UL94 V-0
@Thickness 3.00 mm
V-0
@Thickness 0.118 in
Dry; IEC 60695-11-10

Some of the values displayed above may have been converted from their original units and/or rounded in order to display the information in a consistent format. Users requiring more precise data for scientific or engineering calculations can click on the property value to see the original value as well as raw conversions to equivalent units. We advise that you only use the original value or one of its raw conversions in your calculations to minimize rounding error. We also ask that you refer to MatWeb's terms of use regarding this information. Click here to view all the property values for this datasheet as they were originally entered into MatWeb.

PDSM7907 / 291343

Proto3000 – 3D Engineering Solutions

Please read our License Agreement regarding materials data and our Privacy Policy. Questions or comments about MatWeb? Please contact us at webmaster@matweb.com. We appreciate your input.

The contents of this web site, the MatWeb logo, and "MatWeb" are Copyright 1996-2024 by MatWeb, LLC. MatWeb is intended for personal, non-commercial use. The contents, results, and technical data from this site may not be reproduced either electronically, photographically or substantively without permission from MatWeb, LLC.